{"id":3769,"date":"2025-09-09T13:39:59","date_gmt":"2025-09-09T11:39:59","guid":{"rendered":"https:\/\/www.mylab-analyzer.de\/products-solutions\/mylab-nir-spectrometer\/"},"modified":"2026-02-11T16:33:35","modified_gmt":"2026-02-11T15:33:35","slug":"mylab-nir-spectrometer","status":"publish","type":"page","link":"https:\/\/www.mylab-analyzer.de\/en\/products-solutions\/mylab-nir-spectrometer\/","title":{"rendered":"mylab NIR spectrometer"},"content":{"rendered":"\n<div style=\"height:70px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<h1 class=\"wp-block-heading has-blue-color has-text-color has-link-color wp-elements-389b0addc9dc675167ef3214309fda22\" id=\"h-mylab-nir-analyzer\"><strong>mylab NIR Analyzer<\/strong><\/h1>\n\n<h2 class=\"wp-block-heading has-blue-color has-text-color has-link-color has-medium-font-size wp-elements-5651ab80b9989473a93aa1da437a4c1a\" id=\"h-robustes-nir-spektrometer-fur-die-schnelle-bestimmung-von-inhaltsstoffen\"><strong>  Robust NIR spectrometer for the rapid determination of ingredients<\/strong><\/h2>\n\n<div style=\"height:45px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<div class=\"wp-block-media-text has-media-on-the-right is-stacked-on-mobile\" style=\"grid-template-columns:auto 46%\"><div class=\"wp-block-media-text__content\">\n<p>The mylab NIR Analyzer is a compact, high-performance NIR spectrometer for the rapid detection of ingredients in solid, porous and liquid media.  <\/p>\n\n\n\n<p>Within less than 2 seconds, a sample is analyzed non-destructively both qualitatively and quantitatively for <a href=\"#h-welche-inhaltsstoffe-konnen-mit-nirs-analysiert-werden\">various parameters<\/a>.<\/p>\n\n\n\n<p>This robust NIR spectrometer is therefore a time and cost-saving alternative to a large number of analytical wet-chemical methods.<\/p>\n\n\n\n<p>The mylab NIR analyzer offers an attractive price-performance ratio with professional performance in near-infrared spectroscopy.<\/p>\n\n\n\n<p>Developed and produced in Germany under ISO 9001:2015 quality standard.<\/p>\n<\/div><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"985\" height=\"1024\" src=\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/mylab_diary_front_closed-985x1024.jpg\" alt=\"\" class=\"wp-image-4050 size-full\" srcset=\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/mylab_diary_front_closed-985x1024.jpg 985w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/mylab_diary_front_closed-289x300.jpg 289w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/mylab_diary_front_closed-768x799.jpg 768w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/mylab_diary_front_closed-1477x1536.jpg 1477w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/mylab_diary_front_closed-1970x2048.jpg 1970w\" sizes=\"auto, (max-width: 985px) 100vw, 985px\" \/><\/figure><\/div>\n\n<div style=\"height:90px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<div class=\"wp-block-media-text is-stacked-on-mobile\" style=\"grid-template-columns:48% auto\"><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"789\" height=\"1024\" src=\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/mylab_Diary_side_lefttoright_-display-789x1024.jpg\" alt=\"\" class=\"wp-image-4018 size-full\" srcset=\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/mylab_Diary_side_lefttoright_-display-789x1024.jpg 789w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/mylab_Diary_side_lefttoright_-display-231x300.jpg 231w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/mylab_Diary_side_lefttoright_-display-768x997.jpg 768w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/mylab_Diary_side_lefttoright_-display.jpg 1156w\" sizes=\"auto, (max-width: 789px) 100vw, 789px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<h2 class=\"wp-block-heading has-medium-font-size\" id=\"h-vorteile-des-mylab-nir-spektrometers-nbsp\"><strong>Advantages of the mylab NIR spectrometer  <\/strong><\/h2>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Short measuring time<\/li>\n\n\n\n<li>Very simple operation<\/li>\n\n\n\n<li>Large measuring field and high accuracy<\/li>\n\n\n\n<li>Small (W 24 cm x D 33 cm) and light (5.5 kg)<\/li>\n\n\n\n<li>Very strong price-performance ratio  <\/li>\n\n\n\n<li>also mobile, e.g. for outdoor use  <\/li>\n\n\n\n<li>Favorable adaptation for performance-specific requirements<\/li>\n\n\n\n<li>Simple network integration, extensive functions for data export and documentation<\/li>\n<\/ul>\n<\/div><\/div>\n\n<div style=\"height:90px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"326\" src=\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/mylab_bar-1024x326.jpg\" alt=\"\" class=\"wp-image-4144\" srcset=\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/mylab_bar-1024x326.jpg 1024w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/mylab_bar-300x96.jpg 300w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/mylab_bar-768x245.jpg 768w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/mylab_bar-1536x489.jpg 1536w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/mylab_bar-2048x652.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<div style=\"height:90px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<h2 class=\"wp-block-heading\" id=\"h-ein-nir-spektrometer-auch-fur-mobile-einsatze\">An NIR spectrometer also for mobile applications<\/h2>\n\n<div class=\"wp-block-media-text has-media-on-the-right is-stacked-on-mobile\" style=\"grid-template-columns:auto 53%\"><div class=\"wp-block-media-text__content\">\n<p>With its weight of only 5,500 g and a footprint that is only slightly larger than a DIN A4 page (32 cm x 24 cm), the robust mylab NIR analyzer is also suitable for mobile applications.<\/p>\n\n\n\n<p>For NIR spectrometric analyses outside a laboratory, we offer a special hard-shell trolley case (product no.: PR6111) and a suitable power bank for several hours of mobile operation.<\/p>\n\n\n\n<p>An internet connection is not required to operate this NIR spectrometer.<\/p>\n<\/div><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"887\" src=\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/rollkoffer-mit-mylab-nir-analyzer-1-1024x887.jpg\" alt=\"\" class=\"wp-image-4178 size-full\" srcset=\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/rollkoffer-mit-mylab-nir-analyzer-1-1024x887.jpg 1024w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/rollkoffer-mit-mylab-nir-analyzer-1-300x260.jpg 300w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/rollkoffer-mit-mylab-nir-analyzer-1-768x665.jpg 768w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/rollkoffer-mit-mylab-nir-analyzer-1-1536x1330.jpg 1536w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/rollkoffer-mit-mylab-nir-analyzer-1-2048x1774.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure><\/div>\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-d0b3c9c8 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-advgb-accordions advgb-accordions-5dc732cf-f823-4794-8acd-e93136977fbd advgb-accordion-wrapper\">\n<div class=\"wp-block-advgb-accordion-item advgb-accordion-item\" style=\"margin-bottom:10px\"><div class=\"advgb-accordion-header\" style=\"background-color:#F2F2F2;color:#006CC2;border-style:solid;border-width:1px;border-color:#ffffff;border-radius:2px\"><span class=\"advgb-accordion-header-icon accordion-state\"><svg class=\"advgb-icon-closed\" fill=\"#006CC2\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"24\" height=\"24\" viewBox=\"0 0 24 24\"><path opacity=\"0.87\" fill=\"none\" d=\"M24,24H0L0,0l24,0V24z\"><\/path><path d=\"M16.59,8.59L12,13.17L7.41,8.59L6,10l6,6l6-6L16.59,8.59z\"><\/path><\/svg><svg class=\"advgb-icon-opened\" fill=\"#006CC2\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"24\" height=\"24\" viewBox=\"0 0 24 24\"><path opacity=\"0.87\" fill=\"none\" d=\"M24,24H0L0,0l24,0V24z\"><\/path><path d=\"M7.41,15.41L12,10.83l4.59,4.58L18,14l-6-6l-6,6L7.41,15.41z\"><\/path><\/svg><\/span><h3 class=\"advgb-accordion-header-title\" style=\"color:inherit\"><strong>The mylab NIR analyzer series<\/strong> (pre-calibrated NIR spectrometers)<\/h3><\/div><div class=\"advgb-accordion-body\" style=\"border-style:solid !important;border-width:1px !important;border-color:#ffffff !important;border-top:none !important;border-radius:2px !important\">\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-d0b3c9c8 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-blue-color has-text-color has-link-color has-small-font-size wp-elements-26cbf0ba246142f1f2ee57e5c3b67dcb\"><a href=\"https:\/\/www.mylab-analyzer.de\/en\/mylab-nir-analyzer-cereal\/\"><strong>The mylab NIR Analyzer CEREAL<\/strong><\/a><\/p>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><a href=\"https:\/\/www.mylab-analyzer.de\/en\/mylab-nir-analyzer-cereal\/\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"329\" src=\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2024\/11\/Bildschirmfoto-2024-11-22-um-15.03.36-1024x329.png\" alt=\"Picture: mylab NIR-Analyzer CEREAL\" class=\"wp-image-2205\" style=\"object-fit:contain;width:390px;height:175px\" srcset=\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2024\/11\/Bildschirmfoto-2024-11-22-um-15.03.36-1024x329.png 1024w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2024\/11\/Bildschirmfoto-2024-11-22-um-15.03.36-300x96.png 300w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2024\/11\/Bildschirmfoto-2024-11-22-um-15.03.36-768x246.png 768w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2024\/11\/Bildschirmfoto-2024-11-22-um-15.03.36-1536x493.png 1536w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2024\/11\/Bildschirmfoto-2024-11-22-um-15.03.36.png 1552w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-blue-color has-text-color has-link-color has-small-font-size wp-elements-43bb34e2c5ba7e0f31399a31065fc89b\"><a href=\".fzmb.de\/mylab\/mylab-nir-analyzer-custom-fit\/\"><strong>The mylab NIR Analyzer CUSTOM FIT<\/strong><\/a><\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><a href=\".fzmb.de\/mylab\/mylab-nir-analyzer-custom-fit\/\"><img loading=\"lazy\" decoding=\"async\" width=\"1548\" height=\"482\" src=\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2024\/11\/Bildschirmfoto-2024-11-22-um-16.20.47.png\" alt=\"Image: mylab NIR Analyzer CUSTOM FIT\" class=\"wp-image-2246\" style=\"object-fit:contain;width:390px;height:175px\" srcset=\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2024\/11\/Bildschirmfoto-2024-11-22-um-16.20.47.png 1548w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2024\/11\/Bildschirmfoto-2024-11-22-um-16.20.47-300x93.png 300w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2024\/11\/Bildschirmfoto-2024-11-22-um-16.20.47-1024x319.png 1024w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2024\/11\/Bildschirmfoto-2024-11-22-um-16.20.47-768x239.png 768w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2024\/11\/Bildschirmfoto-2024-11-22-um-16.20.47-1536x478.png 1536w\" sizes=\"auto, (max-width: 1548px) 100vw, 1548px\" \/><\/a><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-d0b3c9c8 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-blue-color has-text-color has-link-color has-small-font-size wp-elements-87f693004d4f92e7aa32c590bc200c37\"><a href=\"https:\/\/www.mylab-analyzer.de\/en\/mylab-nir-analyzer\/\"><strong>The mylab NIR Analyzer MEAT<\/strong><\/a><\/p>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><a href=\"https:\/\/www.mylab-analyzer.de\/en\/mylab-nir-analyzer\/\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"323\" src=\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2024\/11\/Bildschirmfoto-2024-11-22-um-15.39.51-1024x323.png\" alt=\"Image: mylab NIR-Analyzer MEAT\" class=\"wp-image-2231\" style=\"object-fit:contain;width:390px;height:175px\" srcset=\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2024\/11\/Bildschirmfoto-2024-11-22-um-15.39.51-1024x323.png 1024w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2024\/11\/Bildschirmfoto-2024-11-22-um-15.39.51-300x95.png 300w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2024\/11\/Bildschirmfoto-2024-11-22-um-15.39.51-768x242.png 768w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2024\/11\/Bildschirmfoto-2024-11-22-um-15.39.51-1536x485.png 1536w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2024\/11\/Bildschirmfoto-2024-11-22-um-15.39.51.png 1552w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-blue-color has-text-color has-link-color has-small-font-size wp-elements-2d756bfe1aeee26b7ce12a6e92019b32\"><a href=\"https:\/\/www.mylab-analyzer.de\/en\/mylab-nir-analyzer-diary\/\"><strong>The mylab NIR Analyzer DIARY<\/strong><\/a><\/p>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><a href=\"https:\/\/www.mylab-analyzer.de\/en\/mylab-nir-analyzer-diary\/\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"323\" src=\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2024\/11\/Bildschirmfoto-2024-11-22-um-15.59.11-1024x323.png\" alt=\"Image: mylab NIR-Analyzer DIARY\" class=\"wp-image-2240\" style=\"object-fit:contain;width:390px;height:175px\" srcset=\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2024\/11\/Bildschirmfoto-2024-11-22-um-15.59.11-1024x323.png 1024w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2024\/11\/Bildschirmfoto-2024-11-22-um-15.59.11-300x95.png 300w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2024\/11\/Bildschirmfoto-2024-11-22-um-15.59.11-768x242.png 768w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2024\/11\/Bildschirmfoto-2024-11-22-um-15.59.11-1536x484.png 1536w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2024\/11\/Bildschirmfoto-2024-11-22-um-15.59.11.png 1548w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<\/div><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-advgb-accordions advgb-accordions-828688dc-c989-458e-a649-ec0fadb8eb52 advgb-accordion-wrapper\" data-collapsed=\"true\">\n<div class=\"wp-block-advgb-accordion-item advgb-accordion-item\" style=\"margin-bottom:0\"><div class=\"advgb-accordion-header\" style=\"background-color:#F2F2F2;color:#006CC2;border-style:solid;border-width:1px;border-color:#ffffff;border-radius:2px\"><span class=\"advgb-accordion-header-icon accordion-state\"><svg class=\"advgb-icon-closed\" fill=\"#006CC2\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"24\" height=\"24\" viewBox=\"0 0 24 24\"><path opacity=\"0.87\" fill=\"none\" d=\"M24,24H0L0,0l24,0V24z\"><\/path><path d=\"M16.59,8.59L12,13.17L7.41,8.59L6,10l6,6l6-6L16.59,8.59z\"><\/path><\/svg><svg class=\"advgb-icon-opened\" fill=\"#006CC2\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"24\" height=\"24\" viewBox=\"0 0 24 24\"><path opacity=\"0.87\" fill=\"none\" d=\"M24,24H0L0,0l24,0V24z\"><\/path><path d=\"M7.41,15.41L12,10.83l4.59,4.58L18,14l-6-6l-6,6L7.41,15.41z\"><\/path><\/svg><\/span><h3 class=\"advgb-accordion-header-title\" style=\"color:inherit\">Background information on NIR spectroscopy<\/h3><\/div><div class=\"advgb-accordion-body\" style=\"border-style:solid !important;border-width:1px !important;border-color:#ffffff !important;border-top:none !important;border-radius:2px !important\">\n<h2 class=\"wp-block-heading has-blue-color has-text-color has-link-color wp-elements-f4b1e783052f9a93a7e59c97a1885d06\" id=\"h-was-ist-nirs\">What is NIRS?<\/h2>\n\n\n\n<p>Near-infrared spectroscopy (NIRS) is a method for the rapid analysis of chemical and physical properties in solids and liquids. It is used in the food and agricultural industries, petrochemistry and medicine, among others. As a fast and cost-effective method, near-infrared spectroscopy has replaced or supplemented a large number of conventional chemical methods.  <\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-wie-funktioniert-eine-nirs-analyse\">How does a NIRS analysis work?<\/h2>\n\n\n\n<p>Light in a wavelength range of 780 &#8211; 3,000 nm is defined as near infrared (NIR). Near-infrared spectroscopy (NIRS) analyzes the interaction between the light and the sample. An NIR spectrometer records the absorption of the light absorbed by the sample at different NIR wavelengths.  <\/p>\n\n\n\n<p>NIR spectroscopy uses the characteristic absorption capacity of functional chemical groups (-CH, -OH, -NH, -SH), e.g. of water, sugars, fats or proteins. Varying concentrations of the different functional groups in a sample influence the absorption and thus lead to an individual NIR spectrum for each sample. The reflected NIR spectra are recorded by a sensitive detector and analyzed using software.  <\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"178\" src=\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2024\/12\/Bildschirmfoto-2024-12-13-um-13.00.30-1024x178.png\" alt=\"\" class=\"wp-image-3109\" srcset=\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2024\/12\/Bildschirmfoto-2024-12-13-um-13.00.30-1024x178.png 1024w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2024\/12\/Bildschirmfoto-2024-12-13-um-13.00.30-300x52.png 300w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2024\/12\/Bildschirmfoto-2024-12-13-um-13.00.30-768x134.png 768w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2024\/12\/Bildschirmfoto-2024-12-13-um-13.00.30-1536x267.png 1536w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2024\/12\/Bildschirmfoto-2024-12-13-um-13.00.30.png 1932w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p><\/p>\n\n\n\n<p class=\"has-small-font-size\"><strong>Fig.1.<\/strong>  Exemplary NIR spectrum (950 nm &#8211; 1,690 nm) of a sample with beet molasses recorded using a mylab NIR analyzer.<\/p>\n\n\n\n<p><\/p>\n\n\n\n<div style=\"height:45px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-welche-inhaltsstoffe-konnen-mit-nirs-analysiert-werden\">Which ingredients can be analyzed with NIRS?<\/h2>\n\n\n\n<p>All components of a sample that absorb NIR light and do not fall below a certain concentration can be determined.  <\/p>\n\n\n\n<p>NIR light is used to excite vibrations in molecules (light absorption). Certain molecules absorb the near-infrared light at certain wavelengths. The substances that can be determined include water (<sub>H2O<\/sub>), fats and oils, sugars (mono-, poly- and oligosaccharides) and proteins. A large number of other organic substances can also be determined, provided they are present in sufficient concentration in the sample. As a &#8220;rule of thumb&#8221;, a detection limit for NIRS is a concentration of around 0.1 %. In certain cases, lower concentrations can also be reliably determined.     <\/p>\n\n\n\n<div style=\"height:35px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p><strong>Application examples<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Fat, proteins, lactose, solids, water and dry matter in milk and dairy products<\/li>\n\n\n\n<li>Carbohydrate content, volatile acids, pH, dry matter, colloids in beet molasses<\/li>\n\n\n\n<li>Glucose, other carbohydrates (mannose, trealose), protein content in compressed yeast  <\/li>\n\n\n\n<li>Fat, proteins and moisture in meat, sausage, cheese and pet food<\/li>\n\n\n\n<li>Moisture, protein and oil content in cereals<\/li>\n\n\n\n<li>Alcohol content in beer and wine<\/li>\n\n\n\n<li>Oxygen content in blood<\/li>\n<\/ul>\n\n\n\n<div style=\"height:45px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-welche-prazision-wird-durch-nirs-analysen-erreicht\">What precision is achieved by NIRS analyses?<\/h2>\n\n\n\n<p><\/p>\n\n\n\n<p>In order to be able to calculate the desired quantitative determination or the concentration of ingredients of a sample from the NIR spectra, the evaluation software must be calibrated. During calibration, NIR spectra are assigned to the values from a reference analysis (e.g. a wet chemical method). The correlation between NIR spectra and the data from the reference method is determined and used to evaluate future NIR spectra.  <\/p>\n\n\n\n<p>The result of the calibration is a mathematical equation, also known as a calibration model. Each calibration model is specific to the product and the parameters to be analyzed and must first be created for each sample type. <\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"513\" src=\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2024\/12\/Abbildung3_Homepage_mylab_Hintergrund_NIRS-1024x513.png\" alt=\"\" class=\"wp-image-3159\" style=\"width:689px;height:auto\" srcset=\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2024\/12\/Abbildung3_Homepage_mylab_Hintergrund_NIRS-1024x513.png 1024w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2024\/12\/Abbildung3_Homepage_mylab_Hintergrund_NIRS-300x150.png 300w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2024\/12\/Abbildung3_Homepage_mylab_Hintergrund_NIRS-768x385.png 768w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2024\/12\/Abbildung3_Homepage_mylab_Hintergrund_NIRS.png 1448w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"has-small-font-size\"><strong>Fig. 2.<\/strong>  Calibration data with a variability of &lt; 1% from 242 NIR and reference measurements for the development of a calibration model for the evaluation software.<\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>NIRS analyses are always calibrated using the reference methods for the desired parameters. A NIRS analysis therefore &#8220;imitates&#8221; the reference method and can therefore only be as accurate as the reference method itself.   <\/p>\n\n\n\n<p>This also means that NIR spectra take on the variability (scattering) of the reference method. As a rule of thumb, NIR-based analysis achieves approximately 1.5 times the variability of the reference method. For example, if the reference method has a scatter of 0.5 %, NIRS analyses can achieve prediction accuracies of 0.75 %.  <\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<\/div><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-advgb-accordions advgb-accordions-ff5e87c1-ded0-4794-a598-27691065fe01 advgb-accordion-wrapper\" data-collapsed=\"true\">\n<div class=\"wp-block-advgb-accordion-item advgb-accordion-item\" style=\"margin-bottom:0\"><div class=\"advgb-accordion-header\" style=\"background-color:#F2F2F2;color:#006CC2;border-style:solid;border-width:1px;border-color:#ffffff;border-radius:2px\"><span class=\"advgb-accordion-header-icon accordion-state\"><svg class=\"advgb-icon-closed\" fill=\"#006CC2\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"24\" height=\"24\" viewBox=\"0 0 24 24\"><path opacity=\"0.87\" fill=\"none\" d=\"M24,24H0L0,0l24,0V24z\"><\/path><path d=\"M16.59,8.59L12,13.17L7.41,8.59L6,10l6,6l6-6L16.59,8.59z\"><\/path><\/svg><svg class=\"advgb-icon-opened\" fill=\"#006CC2\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"24\" height=\"24\" viewBox=\"0 0 24 24\"><path opacity=\"0.87\" fill=\"none\" d=\"M24,24H0L0,0l24,0V24z\"><\/path><path d=\"M7.41,15.41L12,10.83l4.59,4.58L18,14l-6-6l-6,6L7.41,15.41z\"><\/path><\/svg><\/span><h3 class=\"advgb-accordion-header-title\" style=\"color:inherit\">Product and data sheets mylab NIR Analyzer<\/h3><\/div><div class=\"advgb-accordion-body\" style=\"border-style:solid !important;border-width:1px !important;border-color:#ffffff !important;border-top:none !important;border-radius:2px !important\">\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-d0b3c9c8 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-small-font-size\"><strong>Onepager <\/strong>(PDF)<\/p>\n\n\n\n<p class=\"has-small-font-size\">mylab NIR Analyzer (de)<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/Flyer_mylab-NIR-Analyzer_deu.pdf\"><img loading=\"lazy\" decoding=\"async\" width=\"724\" height=\"1024\" src=\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/04\/Bildschirmfoto-2025-04-22-um-14.08.12-724x1024.png\" alt=\"Image of the PDF: Rapid determination of ingredients with the mylab NIR Analyzer using NIR spectroscopy\" class=\"wp-image-3422\" srcset=\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/04\/Bildschirmfoto-2025-04-22-um-14.08.12-724x1024.png 724w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/04\/Bildschirmfoto-2025-04-22-um-14.08.12-212x300.png 212w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/04\/Bildschirmfoto-2025-04-22-um-14.08.12-768x1086.png 768w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/04\/Bildschirmfoto-2025-04-22-um-14.08.12.png 922w\" sizes=\"auto, (max-width: 724px) 100vw, 724px\" \/><\/a><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-small-font-size\"><strong>Onepager<\/strong> (PDF)<\/p>\n\n\n\n<p class=\"has-small-font-size\">mylab NIR Analyzer (en)<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/Flyer_mylab-NIR-Analyzer_eng.pdf\"><img loading=\"lazy\" decoding=\"async\" width=\"729\" height=\"1024\" src=\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/04\/Bildschirmfoto-2025-04-22-um-14.06.57-729x1024.png\" alt=\"Picture of PDF: Rapid Determination of Food Ingredients using the mylab NIR-Analyzer\" class=\"wp-image-3423\" srcset=\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/04\/Bildschirmfoto-2025-04-22-um-14.06.57-729x1024.png 729w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/04\/Bildschirmfoto-2025-04-22-um-14.06.57-214x300.png 214w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/04\/Bildschirmfoto-2025-04-22-um-14.06.57-768x1078.png 768w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/04\/Bildschirmfoto-2025-04-22-um-14.06.57.png 1084w\" sizes=\"auto, (max-width: 729px) 100vw, 729px\" \/><\/a><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-small-font-size\"><strong>Application Note<\/strong> (PDF)<\/p>\n\n\n\n<p class=\"has-small-font-size\">Calibration mylab NIR Analyzer (en)<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/04\/22_04_25_Application-Note_Calibration_mylab-NIR-Analyzer.pdf\"><img loading=\"lazy\" decoding=\"async\" width=\"732\" height=\"1024\" src=\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/04\/Bildschirmfoto-2025-04-22-um-14.33.29-732x1024.png\" alt=\"\" class=\"wp-image-3436\" srcset=\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/04\/Bildschirmfoto-2025-04-22-um-14.33.29-732x1024.png 732w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/04\/Bildschirmfoto-2025-04-22-um-14.33.29-214x300.png 214w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/04\/Bildschirmfoto-2025-04-22-um-14.33.29-768x1075.png 768w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/04\/Bildschirmfoto-2025-04-22-um-14.33.29.png 926w\" sizes=\"auto, (max-width: 732px) 100vw, 732px\" \/><\/a><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-d0b3c9c8 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-small-font-size\"><strong>Instrument Specs <\/strong>(PDF)<\/p>\n\n\n\n<p class=\"has-small-font-size\">mylab NIR Analyzer (en)<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/Instrument_Specs_mylab_NIR-Analyzer_2024.pdf\"><img loading=\"lazy\" decoding=\"async\" width=\"734\" height=\"1024\" src=\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/Bildschirmfoto-2025-09-16-um-14.36.01-734x1024.jpg\" alt=\"mylab NIR Analyzer, NIR Septrometer Instrument Specs\" class=\"wp-image-4127\" srcset=\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/Bildschirmfoto-2025-09-16-um-14.36.01-734x1024.jpg 734w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/Bildschirmfoto-2025-09-16-um-14.36.01-215x300.jpg 215w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/Bildschirmfoto-2025-09-16-um-14.36.01-768x1071.jpg 768w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/Bildschirmfoto-2025-09-16-um-14.36.01-1101x1536.jpg 1101w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/Bildschirmfoto-2025-09-16-um-14.36.01.jpg 1246w\" sizes=\"auto, (max-width: 734px) 100vw, 734px\" \/><\/a><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-small-font-size\">Application Note (PDF)<\/p>\n\n\n\n<p class=\"has-small-font-size\">NIRS analysis of meat and bone meal (en)<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"723\" height=\"1024\" src=\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/Bildschirmfoto-2025-09-22-um-13.58.28-1-723x1024.png\" alt=\"\" class=\"wp-image-4297\" srcset=\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/Bildschirmfoto-2025-09-22-um-13.58.28-1-723x1024.png 723w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/Bildschirmfoto-2025-09-22-um-13.58.28-1-212x300.png 212w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/Bildschirmfoto-2025-09-22-um-13.58.28-1-768x1087.png 768w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/Bildschirmfoto-2025-09-22-um-13.58.28-1.png 914w\" sizes=\"auto, (max-width: 723px) 100vw, 723px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-small-font-size\"><\/p>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:35px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"has-small-font-size\"><\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<\/div><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-advgb-accordions advgb-accordions-05ac2adc-2c61-4e7a-a19f-21dbfd9b6f00 advgb-accordion-wrapper\" data-collapsed=\"true\">\n<div class=\"wp-block-advgb-accordion-item advgb-accordion-item\" style=\"margin-bottom:0\"><div class=\"advgb-accordion-header\" style=\"background-color:#F2F2F2;color:#006CC2;border-style:solid;border-width:1px;border-color:#ffffff;border-radius:2px\"><span class=\"advgb-accordion-header-icon accordion-state\"><svg class=\"advgb-icon-closed\" fill=\"#006CC2\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"24\" height=\"24\" viewBox=\"0 0 24 24\"><path opacity=\"0.87\" fill=\"none\" d=\"M24,24H0L0,0l24,0V24z\"><\/path><path d=\"M16.59,8.59L12,13.17L7.41,8.59L6,10l6,6l6-6L16.59,8.59z\"><\/path><\/svg><svg class=\"advgb-icon-opened\" fill=\"#006CC2\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"24\" height=\"24\" viewBox=\"0 0 24 24\"><path opacity=\"0.87\" fill=\"none\" d=\"M24,24H0L0,0l24,0V24z\"><\/path><path d=\"M7.41,15.41L12,10.83l4.59,4.58L18,14l-6-6l-6,6L7.41,15.41z\"><\/path><\/svg><\/span><h3 class=\"advgb-accordion-header-title\" style=\"color:inherit\">Accessories mylab NIR Analyzer<\/h3><\/div><div class=\"advgb-accordion-body\" style=\"border-style:solid !important;border-width:1px !important;border-color:#ffffff !important;border-top:none !important;border-radius:2px !important\">\n<div style=\"height:49px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"has-small-font-size\"><\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-d0b3c9c8 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-small-font-size\"><strong>Light source for mylab NIR analyzer<\/strong><\/p>\n\n\n\n<p class=\"has-small-font-size\">Product number: PR6113<\/p>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"646\" src=\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/ersatzlampe_mylab_NIR-Analyzer-1024x646.jpg\" alt=\"Photo replacement lamp for NIR spectrometer mylab NIR-Analyzer\" class=\"wp-image-4243\" style=\"width:233px;height:auto\" srcset=\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/ersatzlampe_mylab_NIR-Analyzer-1024x646.jpg 1024w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/ersatzlampe_mylab_NIR-Analyzer-300x189.jpg 300w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/ersatzlampe_mylab_NIR-Analyzer-768x485.jpg 768w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/ersatzlampe_mylab_NIR-Analyzer-1536x969.jpg 1536w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/ersatzlampe_mylab_NIR-Analyzer-2048x1292.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-small-font-size\"><strong>Sample dish made of special glass  <\/strong><\/p>\n\n\n\n<p class=\"has-small-font-size\">Product number: PR6112<\/p>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"646\" src=\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/Ersatzschale-fuer-Proben-aus-Spezialglas-1024x646.jpg\" alt=\"Photo Special glass dish for samples NIRS mylab NIR Analyzer\" class=\"wp-image-4245\" style=\"width:236px;height:auto\" srcset=\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/Ersatzschale-fuer-Proben-aus-Spezialglas-1024x646.jpg 1024w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/Ersatzschale-fuer-Proben-aus-Spezialglas-300x189.jpg 300w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/Ersatzschale-fuer-Proben-aus-Spezialglas-768x485.jpg 768w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/Ersatzschale-fuer-Proben-aus-Spezialglas-1536x969.jpg 1536w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/Ersatzschale-fuer-Proben-aus-Spezialglas-2048x1292.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-small-font-size\"><strong>Trolley case for<\/strong> <strong>mylab NIR Analyzer<\/strong><\/p>\n\n\n\n<p class=\"has-small-font-size\">Product number: PR6111<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"865\" height=\"1024\" src=\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/mylab_nir-analyzer_rollkoffer_hell-865x1024.jpg\" alt=\"\" class=\"wp-image-4168\" srcset=\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/mylab_nir-analyzer_rollkoffer_hell-865x1024.jpg 865w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/mylab_nir-analyzer_rollkoffer_hell-253x300.jpg 253w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/mylab_nir-analyzer_rollkoffer_hell-768x910.jpg 768w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/mylab_nir-analyzer_rollkoffer_hell.jpg 1019w\" sizes=\"auto, (max-width: 865px) 100vw, 865px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<p class=\"has-small-font-size\"><strong>Filter for mylab analyzer<\/strong><\/p>\n\n\n\n<p class=\"has-small-font-size\">Product number: PR6114<\/p>\n\n\n\n<p><\/p>\n\n\n\n<div style=\"height:35px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<\/div><\/div>\n<\/div>\n\n\n\n<div style=\"height:120px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-advgb-accordions advgb-accordions-df6344c1-fa2f-495f-ae2a-a3442d067b38 advgb-accordion-wrapper\">\n<div class=\"wp-block-advgb-accordion-item advgb-accordion-item\" style=\"margin-bottom:0\"><div class=\"advgb-accordion-header\" style=\"background-color:#F2F2F2;color:#006CC2;border-style:solid;border-width:1px;border-color:#ffffff;border-radius:2px\"><span class=\"advgb-accordion-header-icon accordion-state\"><svg class=\"advgb-icon-closed\" fill=\"#006CC2\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"24\" height=\"24\" viewBox=\"0 0 24 24\"><path opacity=\"0.87\" fill=\"none\" d=\"M24,24H0L0,0l24,0V24z\"><\/path><path d=\"M16.59,8.59L12,13.17L7.41,8.59L6,10l6,6l6-6L16.59,8.59z\"><\/path><\/svg><svg class=\"advgb-icon-opened\" fill=\"#006CC2\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"24\" height=\"24\" viewBox=\"0 0 24 24\"><path opacity=\"0.87\" fill=\"none\" d=\"M24,24H0L0,0l24,0V24z\"><\/path><path d=\"M7.41,15.41L12,10.83l4.59,4.58L18,14l-6-6l-6,6L7.41,15.41z\"><\/path><\/svg><\/span><h3 class=\"advgb-accordion-header-title\" style=\"color:inherit\">Contact for further information and offers<\/h3><\/div><div class=\"advgb-accordion-body\" style=\"border-style:solid !important;border-width:1px !important;border-color:#ffffff !important;border-top:none !important;border-radius:2px !important\">\n<div class=\"wp-block-media-text has-media-on-the-right is-stacked-on-mobile\"><div class=\"wp-block-media-text__content\">\n<div style=\"height:32px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>Our team of product specialists is at your disposal for questions and quotations.  <\/p>\n\n\n\n<p><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-ihr-ansprechpartner\">Your contact person<\/h2>\n\n\n\n<p>Alexander M\u00fccke, Product Manager<\/p>\n\n\n\n<p>phone +49 3603 &#8211; 833 193<\/p>\n\n\n\n<p>Email <a target=\"_blank\" rel=\"noreferrer noopener\">amuecke@fzmb.de<\/a><\/p>\n\n\n\n<p><\/p>\n<\/div><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"683\" src=\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2024\/11\/Bild-Geraete-1024x683.jpg\" alt=\"\" class=\"wp-image-2103 size-full\" srcset=\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2024\/11\/Bild-Geraete-1024x683.jpg 1024w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2024\/11\/Bild-Geraete-300x200.jpg 300w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2024\/11\/Bild-Geraete-768x512.jpg 768w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2024\/11\/Bild-Geraete-1536x1024.jpg 1536w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2024\/11\/Bild-Geraete-2048x1365.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure><\/div>\n\n\n\n<p><\/p>\n<\/div><\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<div style=\"height:15px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>mylab NIR Analyzer Robust NIR spectrometer for the rapid determination of ingredients The mylab NIR Analyzer is a compact, high-performance NIR spectrometer for the rapid detection of ingredients in solid, porous and liquid media. Within less than 2 seconds, a sample is analyzed non-destructively both qualitatively and quantitatively for various parameters. This robust NIR spectrometer [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":0,"parent":3641,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"advgb_blocks_editor_width":"","advgb_blocks_columns_visual_guide":"","footnotes":""},"class_list":["post-3769","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v23.1 (Yoast SEO v27.0) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>compact NIR spectrometer<\/title>\n<meta name=\"description\" content=\"Professional NIR spectrometer for rapid determination of ingredients. Also suitable for mobile use. Excellent price\/performance ratio.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.mylab-analyzer.de\/en\/products-solutions\/mylab-nir-spectrometer\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"mylab NIR spectrometer\" \/>\n<meta property=\"og:description\" content=\"Powerful, compact but inexpensive NIR spectrometer for rapid determination of ingredients (qualitative + quantitative).\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.mylab-analyzer.de\/en\/products-solutions\/mylab-nir-spectrometer\/\" \/>\n<meta property=\"og:site_name\" content=\"mylab Systeml\u00f6sungen\" \/>\n<meta property=\"article:modified_time\" content=\"2026-02-11T15:33:35+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2024\/11\/Bildschirmfoto-2024-11-25-um-16.03.12-1024x1003.png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.mylab-analyzer.de\/en\/products-solutions\/mylab-nir-spectrometer\/\",\"url\":\"https:\/\/www.mylab-analyzer.de\/en\/products-solutions\/mylab-nir-spectrometer\/\",\"name\":\"compact NIR spectrometer\",\"isPartOf\":{\"@id\":\"https:\/\/www.mylab-analyzer.de\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.mylab-analyzer.de\/en\/products-solutions\/mylab-nir-spectrometer\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.mylab-analyzer.de\/en\/products-solutions\/mylab-nir-spectrometer\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/mylab_diary_front_closed-985x1024.jpg\",\"datePublished\":\"2025-09-09T11:39:59+00:00\",\"dateModified\":\"2026-02-11T15:33:35+00:00\",\"description\":\"Professional NIR spectrometer for rapid determination of ingredients. Also suitable for mobile use. Excellent price\/performance ratio.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.mylab-analyzer.de\/en\/products-solutions\/mylab-nir-spectrometer\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.mylab-analyzer.de\/en\/products-solutions\/mylab-nir-spectrometer\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.mylab-analyzer.de\/en\/products-solutions\/mylab-nir-spectrometer\/#primaryimage\",\"url\":\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/mylab_diary_front_closed-985x1024.jpg\",\"contentUrl\":\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/mylab_diary_front_closed-985x1024.jpg\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.mylab-analyzer.de\/en\/products-solutions\/mylab-nir-spectrometer\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\/\/www.mylab-analyzer.de\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products &amp; Solutions\",\"item\":\"https:\/\/www.mylab-analyzer.de\/en\/products-solutions\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"mylab NIR spectrometer\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.mylab-analyzer.de\/en\/#website\",\"url\":\"https:\/\/www.mylab-analyzer.de\/en\/\",\"name\":\"mylab Systeml\u00f6sungen\",\"description\":\"Produkte und Services der fzmb GmbH\",\"publisher\":{\"@id\":\"https:\/\/www.mylab-analyzer.de\/en\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.mylab-analyzer.de\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.mylab-analyzer.de\/en\/#organization\",\"name\":\"mylab Systeml\u00f6sungen\",\"url\":\"https:\/\/www.mylab-analyzer.de\/en\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.mylab-analyzer.de\/en\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2022\/11\/fzmb_Logo.svg\",\"contentUrl\":\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2022\/11\/fzmb_Logo.svg\",\"caption\":\"mylab Systeml\u00f6sungen\"},\"image\":{\"@id\":\"https:\/\/www.mylab-analyzer.de\/en\/#\/schema\/logo\/image\/\"}}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"compact NIR spectrometer","description":"Professional NIR spectrometer for rapid determination of ingredients. Also suitable for mobile use. Excellent price\/performance ratio.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.mylab-analyzer.de\/en\/products-solutions\/mylab-nir-spectrometer\/","og_locale":"en_US","og_type":"article","og_title":"mylab NIR spectrometer","og_description":"Powerful, compact but inexpensive NIR spectrometer for rapid determination of ingredients (qualitative + quantitative).","og_url":"https:\/\/www.mylab-analyzer.de\/en\/products-solutions\/mylab-nir-spectrometer\/","og_site_name":"mylab Systeml\u00f6sungen","article_modified_time":"2026-02-11T15:33:35+00:00","og_image":[{"url":"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2024\/11\/Bildschirmfoto-2024-11-25-um-16.03.12-1024x1003.png","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.mylab-analyzer.de\/en\/products-solutions\/mylab-nir-spectrometer\/","url":"https:\/\/www.mylab-analyzer.de\/en\/products-solutions\/mylab-nir-spectrometer\/","name":"compact NIR spectrometer","isPartOf":{"@id":"https:\/\/www.mylab-analyzer.de\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.mylab-analyzer.de\/en\/products-solutions\/mylab-nir-spectrometer\/#primaryimage"},"image":{"@id":"https:\/\/www.mylab-analyzer.de\/en\/products-solutions\/mylab-nir-spectrometer\/#primaryimage"},"thumbnailUrl":"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/mylab_diary_front_closed-985x1024.jpg","datePublished":"2025-09-09T11:39:59+00:00","dateModified":"2026-02-11T15:33:35+00:00","description":"Professional NIR spectrometer for rapid determination of ingredients. Also suitable for mobile use. Excellent price\/performance ratio.","breadcrumb":{"@id":"https:\/\/www.mylab-analyzer.de\/en\/products-solutions\/mylab-nir-spectrometer\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.mylab-analyzer.de\/en\/products-solutions\/mylab-nir-spectrometer\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.mylab-analyzer.de\/en\/products-solutions\/mylab-nir-spectrometer\/#primaryimage","url":"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/mylab_diary_front_closed-985x1024.jpg","contentUrl":"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/mylab_diary_front_closed-985x1024.jpg"},{"@type":"BreadcrumbList","@id":"https:\/\/www.mylab-analyzer.de\/en\/products-solutions\/mylab-nir-spectrometer\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/www.mylab-analyzer.de\/en\/"},{"@type":"ListItem","position":2,"name":"Products &amp; Solutions","item":"https:\/\/www.mylab-analyzer.de\/en\/products-solutions\/"},{"@type":"ListItem","position":3,"name":"mylab NIR spectrometer"}]},{"@type":"WebSite","@id":"https:\/\/www.mylab-analyzer.de\/en\/#website","url":"https:\/\/www.mylab-analyzer.de\/en\/","name":"mylab Systeml\u00f6sungen","description":"Produkte und Services der fzmb GmbH","publisher":{"@id":"https:\/\/www.mylab-analyzer.de\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.mylab-analyzer.de\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.mylab-analyzer.de\/en\/#organization","name":"mylab Systeml\u00f6sungen","url":"https:\/\/www.mylab-analyzer.de\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.mylab-analyzer.de\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2022\/11\/fzmb_Logo.svg","contentUrl":"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2022\/11\/fzmb_Logo.svg","caption":"mylab Systeml\u00f6sungen"},"image":{"@id":"https:\/\/www.mylab-analyzer.de\/en\/#\/schema\/logo\/image\/"}}]}},"acf":[],"coauthors":[],"author_meta":{"author_link":"https:\/\/www.mylab-analyzer.de\/en\/author\/heise\/","display_name":"heise"},"relative_dates":{"created":"Posted 8 months ago","modified":"Updated 3 months ago"},"absolute_dates":{"created":"Posted on 9. September 2025","modified":"Updated on 11. February 2026"},"absolute_dates_time":{"created":"Posted on 9. September 2025 13:39","modified":"Updated on 11. February 2026 16:33"},"featured_img_caption":"","featured_img":false,"series_order":"","_links":{"self":[{"href":"https:\/\/www.mylab-analyzer.de\/en\/wp-json\/wp\/v2\/pages\/3769","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.mylab-analyzer.de\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.mylab-analyzer.de\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.mylab-analyzer.de\/en\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.mylab-analyzer.de\/en\/wp-json\/wp\/v2\/comments?post=3769"}],"version-history":[{"count":103,"href":"https:\/\/www.mylab-analyzer.de\/en\/wp-json\/wp\/v2\/pages\/3769\/revisions"}],"predecessor-version":[{"id":4424,"href":"https:\/\/www.mylab-analyzer.de\/en\/wp-json\/wp\/v2\/pages\/3769\/revisions\/4424"}],"up":[{"embeddable":true,"href":"https:\/\/www.mylab-analyzer.de\/en\/wp-json\/wp\/v2\/pages\/3641"}],"wp:attachment":[{"href":"https:\/\/www.mylab-analyzer.de\/en\/wp-json\/wp\/v2\/media?parent=3769"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}