{"id":3637,"date":"2024-07-16T09:08:59","date_gmt":"2024-07-16T07:08:59","guid":{"rendered":"https:\/\/www.mylab-analyzer.de\/mylab-nir-analyzer\/"},"modified":"2025-09-19T16:30:41","modified_gmt":"2025-09-19T14:30:41","slug":"mylab-nir-analyzer","status":"publish","type":"page","link":"https:\/\/www.mylab-analyzer.de\/en\/mylab-nir-analyzer\/","title":{"rendered":"mylab NIR Analyzer"},"content":{"rendered":"\n<h1 class=\"wp-block-heading has-blue-color has-text-color has-link-color has-x-large-font-size wp-elements-a5711b82e72a6484f6fee6fb301e78ea\" id=\"h-nir-spektrometer-fur-die-qs-von-fleisch-und-wurstwaren\">NIR spectrometer for the QA of meat and sausage products<\/h1>\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<div class=\"wp-block-media-text has-media-on-the-right is-stacked-on-mobile is-image-fill\" style=\"grid-template-columns:auto 43%\"><div class=\"wp-block-media-text__content\">\n<p class=\"wp-block-paragraph\">The NIR spectrometer<strong> <\/strong>mylab NIR-Analyzer MEAT enables fast, precise and non-destructive quality control of meat and sausage products.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The powerful, yet compact and very robust device is ideal for use in incoming goods, production and outgoing goods.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Applications range from raw material testing, recipe control and product development to quality assurance of end products.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The mylab NIR-Analyzer MEAT is calibrated for products such as minced or homogenized fresh meat as well as raw, scalded and cooked sausage from beef and pork.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n<\/div><figure class=\"wp-block-media-text__media\" style=\"background-image:url(https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2024\/08\/ML_BL-19-von-30-1024x683.jpg);background-position:50% 50%\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"683\" src=\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2024\/08\/ML_BL-19-von-30-1024x683.jpg\" alt=\"\" class=\"wp-image-2067 size-full\" srcset=\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2024\/08\/ML_BL-19-von-30-1024x683.jpg 1024w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2024\/08\/ML_BL-19-von-30-300x200.jpg 300w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2024\/08\/ML_BL-19-von-30-768x512.jpg 768w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2024\/08\/ML_BL-19-von-30-1536x1024.jpg 1536w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2024\/08\/ML_BL-19-von-30-2048x1365.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure><\/div>\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"323\" src=\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2024\/11\/Bildschirmfoto-2024-11-22-um-15.39.51-1024x323.png\" alt=\"\" class=\"wp-image-2231\" srcset=\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2024\/11\/Bildschirmfoto-2024-11-22-um-15.39.51-1024x323.png 1024w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2024\/11\/Bildschirmfoto-2024-11-22-um-15.39.51-300x95.png 300w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2024\/11\/Bildschirmfoto-2024-11-22-um-15.39.51-768x242.png 768w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2024\/11\/Bildschirmfoto-2024-11-22-um-15.39.51-1536x485.png 1536w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2024\/11\/Bildschirmfoto-2024-11-22-um-15.39.51.png 1552w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<h1 class=\"wp-block-heading has-blue-color has-text-color has-link-color has-x-large-font-size wp-elements-f3306ec95f5de0b205c1ef2e047d1c97\" id=\"h-vorkalibrierte-parameter-fur-wurst-und-fleischprodukte\">Pre-calibrated parameters for sausage and meat products<\/h1>\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<p class=\"wp-block-paragraph\">The mylab NIR Analyzer MEAT is pre-calibrated for the quality control of minced or homogenized fresh meat as well as raw, scalded and cooked sausage from beef and pork.<\/p>\n\n<p class=\"wp-block-paragraph\">The following provisions are implemented:<\/p>\n\n<div class=\"wp-block-media-text has-media-on-the-right is-stacked-on-mobile\" style=\"grid-template-columns:auto 40%\"><div class=\"wp-block-media-text__content\">\n<ul class=\"wp-block-list\">\n<li>Nutritional values (BIG 7) in accordance with EU Regulation 1169\/2011: <em>calorific value in kJ and kcal, fat, saturated fatty acids, <br\/>Carbohydrates, of which sugar, protein, fat<\/em><\/li>\n\n\n\n<li>Dry matter, organic dry matter, water, extraneous water, ash<\/li>\n\n\n\n<li>Fat-protein ratio, water-protein ratio<\/li>\n\n\n\n<li>BEFFE (connective tissue protein) and BEFFE in the FE<\/li>\n\n\n\n<li>pH value, aw value<\/li>\n\n\n\n<li>Hydroxyproline<\/li>\n<\/ul>\n<\/div><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"819\" height=\"1024\" src=\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/mylab_diary_front-1-819x1024.jpg\" alt=\"\" class=\"wp-image-4046 size-full\" srcset=\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/mylab_diary_front-1-819x1024.jpg 819w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/mylab_diary_front-1-240x300.jpg 240w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/mylab_diary_front-1-768x960.jpg 768w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/mylab_diary_front-1-1228x1536.jpg 1228w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/mylab_diary_front-1-1638x2048.jpg 1638w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/mylab_diary_front-1-scaled.jpg 2047w\" sizes=\"auto, (max-width: 819px) 100vw, 819px\" \/><\/figure><\/div>\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<p class=\"wp-block-paragraph\">Our team of experts will carry out further calibrations and adaptations to specific products for you at low cost. If laboratory analyses are required, these can be carried out in our <a href=\"http:\/\/www.Lebensmittellab.de\">accredited test laboratory for foodstuffs <\/a>. <\/p>\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<div class=\"wp-block-advgb-accordions advgb-accordions-7fffb3a6-a8e9-4ebb-8bf4-d304594f5f38 advgb-accordion-wrapper\" data-collapsed=\"true\">\n<div class=\"wp-block-advgb-accordion-item advgb-accordion-item\" style=\"margin-bottom:15px\"><div class=\"advgb-accordion-header\" style=\"background-color:#F2F2F2;color:#006CC2;border-style:solid;border-width:1px;border-radius:2px\"><span class=\"advgb-accordion-header-icon\"><svg fill=\"#006CC2\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"24\" height=\"24\" viewBox=\"0 0 24 24\"><path opacity=\"0.87\" fill=\"none\" d=\"M24,24H0L0,0l24,0V24z\"><\/path><path d=\"M16.59,8.59L12,13.17L7.41,8.59L6,10l6,6l6-6L16.59,8.59z\"><\/path><\/svg><\/span><h2 class=\"advgb-accordion-header-title\" style=\"color:inherit\">Application Note<\/h2><\/div><div class=\"advgb-accordion-body\" style=\"border-style:solid !important;border-width:1px !important;border-color:undefined !important;border-top:none !important;border-radius:2px !important\">\n<div style=\"height:15px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-media-text has-media-on-the-right is-stacked-on-mobile\" style=\"grid-template-columns:auto 35%\"><div class=\"wp-block-media-text__content\">\n<p class=\"wp-block-paragraph\"><strong>Chapter: Training the mylab-NIR-Analyzer for Analysis of Meat and Meat Products<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><em>The mylab NIR-Analyzer was trained on 650 samples of meat and meat products to analyze<\/em> <em>the following parameters: fat, saturated fats, dry matter, sugar, ash, protein, MPDCP (meat<\/em> <em>protein devoid of connective tissue protein), water activity (aw-value), pH value, and salt.<\/em><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><em>The reference analyses were conducted by the accredited Prueflabor-fuer-Lebensmitteluntersuchungen as mentioned earlier Table 1 provides an overview of the<\/em> <em>range of values for the &#8220;Meat and Meat Products&#8221; dataset, including the deviations and coefficients of determination for NIRS measurements compared to reference analysis<\/em> (&#8230;).<\/p>\n\n\n\n<p class=\"has-blue-color has-text-color has-link-color wp-elements-2d5874f897177bf1b5e543f01813045a wp-block-paragraph\"><a href=\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/04\/22_04_25_Application-Note_Calibration_mylab-NIR-Analyzer.pdf\">PDF Application Note<\/a><\/p>\n<\/div><figure class=\"wp-block-media-text__media\"><a href=\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/04\/Bildschirmfoto-2025-04-22-um-14.33.29-732x1024.png\"><img loading=\"lazy\" decoding=\"async\" width=\"732\" height=\"1024\" src=\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/04\/Bildschirmfoto-2025-04-22-um-14.33.29-732x1024.png\" alt=\"\" class=\"wp-image-3436 size-full\" srcset=\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/04\/Bildschirmfoto-2025-04-22-um-14.33.29-732x1024.png 732w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/04\/Bildschirmfoto-2025-04-22-um-14.33.29-214x300.png 214w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/04\/Bildschirmfoto-2025-04-22-um-14.33.29-768x1075.png 768w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/04\/Bildschirmfoto-2025-04-22-um-14.33.29.png 926w\" sizes=\"auto, (max-width: 732px) 100vw, 732px\" \/><\/a><\/figure><\/div>\n<\/div><\/div>\n<\/div>\n\n<div style=\"height:32px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<div class=\"wp-block-advgb-accordions advgb-accordions-c7780dca-cb52-4737-8858-5775b322dae5 advgb-accordion-wrapper\" data-collapsed=\"true\">\n<div class=\"wp-block-advgb-accordion-item advgb-accordion-item\" style=\"margin-bottom:15px\"><div class=\"advgb-accordion-header\" style=\"background-color:#F2F2F2;color:#006CC2;border-style:solid;border-width:1px;border-radius:2px\"><span class=\"advgb-accordion-header-icon\"><svg fill=\"#006CC2\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"24\" height=\"24\" viewBox=\"0 0 24 24\"><path opacity=\"0.87\" fill=\"none\" d=\"M24,24H0L0,0l24,0V24z\"><\/path><path d=\"M16.59,8.59L12,13.17L7.41,8.59L6,10l6,6l6-6L16.59,8.59z\"><\/path><\/svg><\/span><h2 class=\"advgb-accordion-header-title\" style=\"color:inherit\">Product specifications<\/h2><\/div><div class=\"advgb-accordion-body\" style=\"border-style:solid !important;border-width:1px !important;border-color:undefined !important;border-top:none !important;border-radius:2px !important\">\n<div style=\"height:15px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-media-text has-media-on-the-right is-stacked-on-mobile\" style=\"grid-template-columns:auto 35%\"><div class=\"wp-block-media-text__content\">\n<h2 class=\"wp-block-heading has-medium-font-size\" id=\"h-nir-spektrometer-mylab-nir-analyzer-meat\"><strong>NIR spectrometer mylab NIR analyzer MEAT<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Product no.<\/strong>PR6101<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Product name<\/strong>: mylab NIR- Analyzer MEAT<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Product scope<\/strong>: 1x mylab NIR analyzer MEAT incl. software and calibration models, 1x power supply unit, 1x power cable, 1x replacement lamp, 5x Petri dish made of special glass, 2x replacement dust filters; 1x operating manual;   <\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Appliance dimensions:<\/strong> L 34 cm x W 24 cm x H 32 cm  <\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Weight:<\/strong> 5.5 kg, 10.2 kg incl. Packing<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Parameters<\/strong>: Determination of 21 parameters for meat and sausage products<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>BIG 7 (according to EU-VO 1169\/2011)<\/li>\n\n\n\n<li>pH value<\/li>\n\n\n\n<li>aW value<\/li>\n\n\n\n<li>BEFFE<\/li>\n\n\n\n<li>BEFFE in FE<\/li>\n\n\n\n<li>Extraneous water (via spring number) &amp; others<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">The basic calibration covers the product groups fresh meat, raw sausage, scalded sausage and cooked sausage of beef and pork.<\/p>\n\n\n\n<p class=\"has-blue-color has-text-color has-link-color wp-elements-173987c3113f5607f84f3071a761f5bd wp-block-paragraph\"><\/p>\n<\/div><figure class=\"wp-block-media-text__media\"><a href=\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/Instrument_Specs_mylab_NIR-Analyzer_2024.pdf\"><img loading=\"lazy\" decoding=\"async\" width=\"734\" height=\"1024\" src=\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/Bildschirmfoto-2025-09-16-um-14.36.01-734x1024.jpg\" alt=\"mylab NIR-Analyzer, NIR-Septrometer Instrument Specs\" class=\"wp-image-4127 size-full\" srcset=\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/Bildschirmfoto-2025-09-16-um-14.36.01-734x1024.jpg 734w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/Bildschirmfoto-2025-09-16-um-14.36.01-215x300.jpg 215w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/Bildschirmfoto-2025-09-16-um-14.36.01-768x1071.jpg 768w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/Bildschirmfoto-2025-09-16-um-14.36.01-1101x1536.jpg 1101w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/Bildschirmfoto-2025-09-16-um-14.36.01.jpg 1246w\" sizes=\"auto, (max-width: 734px) 100vw, 734px\" \/><\/a><\/figure><\/div>\n<\/div><\/div>\n<\/div>\n\n<div style=\"height:32px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<div class=\"wp-block-advgb-accordions advgb-accordions-4ffe02fd-4eae-4237-9d85-6e4484be9651 advgb-accordion-wrapper\" data-collapsed=\"true\">\n<div class=\"wp-block-advgb-accordion-item advgb-accordion-item\" style=\"margin-bottom:0\"><div class=\"advgb-accordion-header\" style=\"background-color:#F2F2F2;color:#006CC2;border-style:solid;border-width:1px;border-radius:2px\"><span class=\"advgb-accordion-header-icon\"><svg fill=\"#006CC2\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"24\" height=\"24\" viewBox=\"0 0 24 24\"><path opacity=\"0.87\" fill=\"none\" d=\"M24,24H0L0,0l24,0V24z\"><\/path><path d=\"M16.59,8.59L12,13.17L7.41,8.59L6,10l6,6l6-6L16.59,8.59z\"><\/path><\/svg><\/span><h2 class=\"advgb-accordion-header-title\" style=\"color:inherit\">Accessories mylab NIR Analyzer<\/h2><\/div><div class=\"advgb-accordion-body\" style=\"border-style:solid !important;border-width:1px !important;border-color:undefined !important;border-top:none !important;border-radius:2px !important\">\n<div style=\"height:49px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\"><\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-f56f613f wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-small-font-size wp-block-paragraph\"><strong>Light source for mylab NIR analyzer<\/strong><\/p>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">Product number: PR6113<\/p>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"646\" src=\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/ersatzlampe_mylab_NIR-Analyzer-1024x646.jpg\" alt=\"Photo replacement lamp for NIR spectrometer mylab NIR-Analyzer\" class=\"wp-image-4243\" style=\"width:233px;height:auto\" srcset=\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/ersatzlampe_mylab_NIR-Analyzer-1024x646.jpg 1024w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/ersatzlampe_mylab_NIR-Analyzer-300x189.jpg 300w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/ersatzlampe_mylab_NIR-Analyzer-768x485.jpg 768w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/ersatzlampe_mylab_NIR-Analyzer-1536x969.jpg 1536w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/ersatzlampe_mylab_NIR-Analyzer-2048x1292.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-small-font-size wp-block-paragraph\"><strong>Sample dish made of special glass  <\/strong><\/p>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">Product number: PR6112<\/p>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"646\" src=\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/Ersatzschale-fuer-Proben-aus-Spezialglas-1024x646.jpg\" alt=\"Photo Special glass dish for samples NIRS mylab NIR Analyzer\" class=\"wp-image-4245\" style=\"width:236px;height:auto\" srcset=\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/Ersatzschale-fuer-Proben-aus-Spezialglas-1024x646.jpg 1024w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/Ersatzschale-fuer-Proben-aus-Spezialglas-300x189.jpg 300w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/Ersatzschale-fuer-Proben-aus-Spezialglas-768x485.jpg 768w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/Ersatzschale-fuer-Proben-aus-Spezialglas-1536x969.jpg 1536w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/Ersatzschale-fuer-Proben-aus-Spezialglas-2048x1292.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-small-font-size wp-block-paragraph\"><strong>Trolley case for<\/strong> <strong>mylab NIR Analyzer<\/strong><\/p>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">Product number: PR6111<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"865\" height=\"1024\" src=\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/mylab_nir-analyzer_rollkoffer_hell-865x1024.jpg\" alt=\"\" class=\"wp-image-4168\" srcset=\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/mylab_nir-analyzer_rollkoffer_hell-865x1024.jpg 865w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/mylab_nir-analyzer_rollkoffer_hell-253x300.jpg 253w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/mylab_nir-analyzer_rollkoffer_hell-768x910.jpg 768w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/mylab_nir-analyzer_rollkoffer_hell.jpg 1019w\" sizes=\"auto, (max-width: 865px) 100vw, 865px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\"><strong>Filter for mylab analyzer<\/strong><\/p>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">Product number: PR6114<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<div style=\"height:35px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<\/div><\/div>\n<\/div>\n\n<div style=\"height:120px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-advgb-accordions advgb-accordions-da44b385-9a41-4dbd-8958-cab0d437c298 advgb-accordion-wrapper\">\n\n<div class=\"wp-block-advgb-accordion-item advgb-accordion-item\" style=\"margin-bottom:15px\"><div class=\"advgb-accordion-header\" style=\"background-color:#F2F2F2;color:#006CC2;border-style:solid;border-width:1px;border-radius:2px\"><span class=\"advgb-accordion-header-icon\"><svg fill=\"#006CC2\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"24\" height=\"24\" viewBox=\"0 0 24 24\"><path opacity=\"0.87\" fill=\"none\" d=\"M24,24H0L0,0l24,0V24z\"><\/path><path d=\"M16.59,8.59L12,13.17L7.41,8.59L6,10l6,6l6-6L16.59,8.59z\"><\/path><\/svg><\/span><h2 class=\"advgb-accordion-header-title\" style=\"color:inherit\">Offers and support<\/h2><\/div><div class=\"advgb-accordion-body\" style=\"border-style:solid !important;border-width:1px !important;border-color:undefined !important;border-top:none !important;border-radius:2px !important\">\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-media-text has-media-on-the-right is-stacked-on-mobile\"><div class=\"wp-block-media-text__content\">\n\n<p class=\"wp-block-paragraph\">Our team of product specialists is at your disposal for questions and quotations.  <\/p>\n\n\n<p class=\"wp-block-paragraph\">When integrating and maintaining the <a href=\"https:\/\/www.mylab-analyzer.de\/nir-spektroskopie\/\">mylab NIR analyzer<\/a>, use the integrated Ethernet port for quick and uncomplicated assistance.<\/p>\n\n\n<div style=\"height:45px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<h2 class=\"wp-block-heading has-large-font-size\" id=\"h-ihr-ansprechpartner\">Your contact person<\/h2>\n\n\n<p class=\"wp-block-paragraph\">Alexander M\u00fccke, Product Manager<\/p>\n\n\n<p class=\"wp-block-paragraph\">phone +49 3603 &#8211; 833 193<\/p>\n\n\n<p class=\"wp-block-paragraph\">Email <a href=\"mailto:amuecke@fzmb.de\" target=\"_blank\" rel=\"noreferrer noopener\">amuecke@fzmb.de<\/a><\/p>\n\n<\/div><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"683\" src=\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2024\/11\/Bild-Geraete-1024x683.jpg\" alt=\"\" class=\"wp-image-2103 size-full\" srcset=\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2024\/11\/Bild-Geraete-1024x683.jpg 1024w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2024\/11\/Bild-Geraete-300x200.jpg 300w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2024\/11\/Bild-Geraete-768x512.jpg 768w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2024\/11\/Bild-Geraete-1536x1024.jpg 1536w, https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2024\/11\/Bild-Geraete-2048x1365.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure><\/div>\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<\/div><\/div>\n\n<\/div>\n\n\n<div style=\"height:70px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<h1 class=\"wp-block-heading has-blue-color has-text-color has-link-color has-x-large-font-size wp-elements-dc9390399275ad389b8973d7a23bb6c5\" id=\"h-fazit\">Conclusion<\/h1>\n\n\n<p class=\"wp-block-paragraph\">The compact but powerful mylab NIR-Analyzer MEAT NIR spectrometer offers a fast, accurate and cost-effective solution for meat and sausage quality control and production monitoring in the meat industry. With its versatile functions and customization options, the NIR spectrometer is the ideal choice for meat and sausage producers who want to maintain the highest quality standards. The mylab NIR Analyzer MEAT impresses with its price-performance ratio.    <\/p>\n\n","protected":false},"excerpt":{"rendered":"<p>NIR spectrometer for the QA of meat and sausage products The NIR spectrometer mylab NIR-Analyzer MEAT enables fast, precise and non-destructive quality control of meat and sausage products. The powerful, yet compact and very robust device is ideal for use in incoming goods, production and outgoing goods. Applications range from raw material testing, recipe control [&hellip;]<\/p>\n","protected":false},"author":9,"featured_media":3965,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"advgb_blocks_editor_width":"","advgb_blocks_columns_visual_guide":"","footnotes":""},"class_list":["post-3637","page","type-page","status-publish","has-post-thumbnail","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v23.1 (Yoast SEO v27.0) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>The mylab NIR Analyzer MEAT<\/title>\n<meta name=\"description\" content=\"Robust NIR spectrometer for fast and precise quality control of meat and sausage products. Request a quote now!\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.mylab-analyzer.de\/en\/mylab-nir-analyzer\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"The NIR spectrometer &quot;mylab NIR-Analyzer MEAT&quot;\" \/>\n<meta property=\"og:description\" content=\"Robust system for fast and precise quality analysis of meat and sausage products in the production process. Request a quote now!\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.mylab-analyzer.de\/en\/mylab-nir-analyzer\/\" \/>\n<meta property=\"og:site_name\" content=\"mylab Systeml\u00f6sungen\" \/>\n<meta property=\"article:modified_time\" content=\"2025-09-19T14:30:41+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/mylab_meat.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1130\" \/>\n\t<meta property=\"og:image:height\" content=\"674\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:title\" content=\"mylab NIR Analyzer\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.mylab-analyzer.de\/en\/mylab-nir-analyzer\/\",\"url\":\"https:\/\/www.mylab-analyzer.de\/en\/mylab-nir-analyzer\/\",\"name\":\"The mylab NIR Analyzer MEAT\",\"isPartOf\":{\"@id\":\"https:\/\/www.mylab-analyzer.de\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.mylab-analyzer.de\/en\/mylab-nir-analyzer\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.mylab-analyzer.de\/en\/mylab-nir-analyzer\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/mylab_meat.jpg\",\"datePublished\":\"2024-07-16T07:08:59+00:00\",\"dateModified\":\"2025-09-19T14:30:41+00:00\",\"description\":\"Robust NIR spectrometer for fast and precise quality control of meat and sausage products. Request a quote now!\",\"breadcrumb\":{\"@id\":\"https:\/\/www.mylab-analyzer.de\/en\/mylab-nir-analyzer\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.mylab-analyzer.de\/en\/mylab-nir-analyzer\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.mylab-analyzer.de\/en\/mylab-nir-analyzer\/#primaryimage\",\"url\":\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/mylab_meat.jpg\",\"contentUrl\":\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/mylab_meat.jpg\",\"width\":1130,\"height\":674,\"caption\":\"Bild NIR-Spektrometer mylab NIR-Analyzer MEAT\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.mylab-analyzer.de\/en\/mylab-nir-analyzer\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\/\/www.mylab-analyzer.de\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"mylab NIR Analyzer\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.mylab-analyzer.de\/en\/#website\",\"url\":\"https:\/\/www.mylab-analyzer.de\/en\/\",\"name\":\"mylab Systeml\u00f6sungen\",\"description\":\"Produkte und Services der fzmb GmbH\",\"publisher\":{\"@id\":\"https:\/\/www.mylab-analyzer.de\/en\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.mylab-analyzer.de\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.mylab-analyzer.de\/en\/#organization\",\"name\":\"mylab Systeml\u00f6sungen\",\"url\":\"https:\/\/www.mylab-analyzer.de\/en\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.mylab-analyzer.de\/en\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2022\/11\/fzmb_Logo.svg\",\"contentUrl\":\"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2022\/11\/fzmb_Logo.svg\",\"caption\":\"mylab Systeml\u00f6sungen\"},\"image\":{\"@id\":\"https:\/\/www.mylab-analyzer.de\/en\/#\/schema\/logo\/image\/\"}}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"The mylab NIR Analyzer MEAT","description":"Robust NIR spectrometer for fast and precise quality control of meat and sausage products. Request a quote now!","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.mylab-analyzer.de\/en\/mylab-nir-analyzer\/","og_locale":"en_US","og_type":"article","og_title":"The NIR spectrometer \"mylab NIR-Analyzer MEAT\"","og_description":"Robust system for fast and precise quality analysis of meat and sausage products in the production process. Request a quote now!","og_url":"https:\/\/www.mylab-analyzer.de\/en\/mylab-nir-analyzer\/","og_site_name":"mylab Systeml\u00f6sungen","article_modified_time":"2025-09-19T14:30:41+00:00","og_image":[{"width":1130,"height":674,"url":"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/mylab_meat.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_title":"mylab NIR Analyzer","twitter_misc":{"Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.mylab-analyzer.de\/en\/mylab-nir-analyzer\/","url":"https:\/\/www.mylab-analyzer.de\/en\/mylab-nir-analyzer\/","name":"The mylab NIR Analyzer MEAT","isPartOf":{"@id":"https:\/\/www.mylab-analyzer.de\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.mylab-analyzer.de\/en\/mylab-nir-analyzer\/#primaryimage"},"image":{"@id":"https:\/\/www.mylab-analyzer.de\/en\/mylab-nir-analyzer\/#primaryimage"},"thumbnailUrl":"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/mylab_meat.jpg","datePublished":"2024-07-16T07:08:59+00:00","dateModified":"2025-09-19T14:30:41+00:00","description":"Robust NIR spectrometer for fast and precise quality control of meat and sausage products. Request a quote now!","breadcrumb":{"@id":"https:\/\/www.mylab-analyzer.de\/en\/mylab-nir-analyzer\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.mylab-analyzer.de\/en\/mylab-nir-analyzer\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.mylab-analyzer.de\/en\/mylab-nir-analyzer\/#primaryimage","url":"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/mylab_meat.jpg","contentUrl":"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/mylab_meat.jpg","width":1130,"height":674,"caption":"Bild NIR-Spektrometer mylab NIR-Analyzer MEAT"},{"@type":"BreadcrumbList","@id":"https:\/\/www.mylab-analyzer.de\/en\/mylab-nir-analyzer\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/www.mylab-analyzer.de\/en\/"},{"@type":"ListItem","position":2,"name":"mylab NIR Analyzer"}]},{"@type":"WebSite","@id":"https:\/\/www.mylab-analyzer.de\/en\/#website","url":"https:\/\/www.mylab-analyzer.de\/en\/","name":"mylab Systeml\u00f6sungen","description":"Produkte und Services der fzmb GmbH","publisher":{"@id":"https:\/\/www.mylab-analyzer.de\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.mylab-analyzer.de\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.mylab-analyzer.de\/en\/#organization","name":"mylab Systeml\u00f6sungen","url":"https:\/\/www.mylab-analyzer.de\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.mylab-analyzer.de\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2022\/11\/fzmb_Logo.svg","contentUrl":"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2022\/11\/fzmb_Logo.svg","caption":"mylab Systeml\u00f6sungen"},"image":{"@id":"https:\/\/www.mylab-analyzer.de\/en\/#\/schema\/logo\/image\/"}}]}},"acf":[],"coauthors":[],"author_meta":{"author_link":"https:\/\/www.mylab-analyzer.de\/en\/author\/fmeuche\/","display_name":"fmeuche"},"relative_dates":{"created":"Posted 2 years ago","modified":"Updated 9 months ago"},"absolute_dates":{"created":"Posted on 16. July 2024","modified":"Updated on 19. September 2025"},"absolute_dates_time":{"created":"Posted on 16. July 2024 9:08","modified":"Updated on 19. September 2025 16:30"},"featured_img_caption":"","featured_img":"https:\/\/www.mylab-analyzer.de\/wp-content\/uploads\/sites\/8\/2025\/09\/mylab_meat.jpg","series_order":"","_links":{"self":[{"href":"https:\/\/www.mylab-analyzer.de\/en\/wp-json\/wp\/v2\/pages\/3637","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.mylab-analyzer.de\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.mylab-analyzer.de\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.mylab-analyzer.de\/en\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/www.mylab-analyzer.de\/en\/wp-json\/wp\/v2\/comments?post=3637"}],"version-history":[{"count":28,"href":"https:\/\/www.mylab-analyzer.de\/en\/wp-json\/wp\/v2\/pages\/3637\/revisions"}],"predecessor-version":[{"id":4286,"href":"https:\/\/www.mylab-analyzer.de\/en\/wp-json\/wp\/v2\/pages\/3637\/revisions\/4286"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.mylab-analyzer.de\/en\/wp-json\/wp\/v2\/media\/3965"}],"wp:attachment":[{"href":"https:\/\/www.mylab-analyzer.de\/en\/wp-json\/wp\/v2\/media?parent=3637"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}